ANALISIS DAN PENYELESAIAN DAMPAK HIGH VIBRATION MOTOR DEMINERALIZED WATER TANK PADA SHAFT MOTOR

dc.contributor.authorWaskito, Andre
dc.date.accessioned2023-05-29
dc.date.available2023-05-29
dc.date.issued2022
dc.identifier.uri https://repositori.unhar.ac.id/handle/561/analisis-dan-penyelesaian-dampak-high-vibration-motor-demineralized-water-tank-pada-shaft-motor
dc.description.abstract Tank.Motor Demineralized Water Tank is a tool as a water booster during the process of processing raw water into process water (free of mineral/demineral). This cycle works under conditions of high pressure and temperature Therefore it must be processed following procedures and requirements in accordance with the criteria so as not to experience misalignment which is the main cause of vibration apart from unbalance. Unbalance can be caused by several factors including human error and bending. This research was conducted experimentally by obtaining secondary data which is computational data from the balancing machine. From the results of this study, after being corrected, it was found that plane 1 was 102 mg with an angle of 188° and on plane 2 it was obtained 74.5 mg with an angle of 219°. The meaning of the word plane in the results of this study is the field or side of the motor shaft. Keywords: High Vibration,Unbalance, Motor Demineralized Water Tank. en_US
dc.language.isoenen_US
dc.publisherUniversitas Harapan Medanen_US
dc.subjectHigh Vibration, Motor demin water tanken_US
dc.titleANALISIS DAN PENYELESAIAN DAMPAK HIGH VIBRATION MOTOR DEMINERALIZED WATER TANK PADA SHAFT MOTORen_US
dc.typeSkripsien_US


File In This Item

No Thumbnail
Name 6487fd6c3554dd3f125a4fb2fd26e94dANDRE WASKITO (182320051).docx
Size 5761157 Mb
Format application/vnd.openxmlformats-officedocument.wordprocessingml.document
Description peer_review